ACIntegraCommissioningTestsAndResults Installation of the AC Integra dewar in LG48, Jan/Feb 2010 Commissioning and testing with the VTI * Show zero boil off ...
AMIMagnetPowerSupplyProblems Problems with AMI / Kepco magnet power supplies on the Bluefors LD250 Poseidon and Bluefors XLD fridges. Problem 1 (Poseidon Kepco S...
AVS47BACResistanceBridge AVS 47B Resistance Bridge and related electronics page. Assembling the AVS 47B See user manual here: avs47bmanual_20080411.pdf K100 to ...
AttoCube This page describes the construction of the attocube rotator. It will eventually include wiring diagrams, operation manual, etc. Updated Wiring Diagram ...
AttoCube2degAngleCallibration Thu 17 Sept 2009 First angle calibration using Hall effect Field held at 0.2 T, measured V_H and I at various angles. Fridge at ...
AttoCubeChangingV0AngleAndHeatingTest Changing V0 and callibrating Fridge heating, as well as measuring the noise on the angle readout Noise on angle readout noi...
AttoCubeLabViewControl Running the Software under Labview attocube Labview vi descriptions ANC350_Check Checks the ANC controller is plugged in ANC350_connect ...
BlueForsXLDProbe1AFM Details of the AFMIII on the BlueForsXLD fridge. Specifications of the AFMIII Feixiang to insert Test data Scan data at room temperature o...
BlueForsxLDFridgeInstallationTimelapse Installation of the new BlueFors xLD fridge at UNSW in January 2017.Note this page does not contain technical photos / info...
Cecile2ndDippingAt4K 2nd dipping at 4K in the Heliox Resonance at Room Temperature Remark : I ran the calibration with the averaging on, and the IF Bandwith (10...
Cecile3rdDippingAt4K 3rd dipping at 4K (the right one?) Tests at Room Temperature 2T Measurements Use of the sensitive power supply : 3mV, 10 nA max 4 6 : 2,2...
CecileT452RFDippingAt4K First dipping of the device at 4K in the Heliox Dipping Procedure Check the level of Liquid Helium in the Fridge Open the dewar by tu...
ChemicalLog The following is a list of chemicals stored in the SNF Solvent Chlorobenzene NMP Acetone IPA Resist S1813 AZ6612 AZnLOF2020 PMMA 950K A3 PMMA 950K A...
CoaxialCablesAndPlugs Details on where to order coax cables, plugs, etc. Low triboelectricity cabling These cables give orders of magnitude less noise than ordin...
ComputerDataBackups Update: As of 2017, the primary place that all data, Igor files, presentations etc should be stored is on the network drive, which is backed u...
ComputerSecurity Correct PC security setup The ideal setup for each computer in our group is to partition the hard drive in two drives! One for the system with a...
CryoMechCompressorSwitchToOrFromTownWater Instructions for switching a CryoMech compressor to/from town water. Switch to Town Water Do it in this order to avoid ...
CuNiCoAxCable CuNiCoAxCable coax can be used as high frequency filter in the fridges. The idea is to replace the wiring loom with CuNiCoAxCable coaxes. SC 040/5...
Delft IVVI2 Rack NOTE: Proper setting of the COM port is required. Check with Oleh before use. Measurement rack designed for DC measurements of high resistance s...
Femto DDPCA S variable gain current preamp Features: variable gain, symmetric biasing 10 V on the DC bias port will result in 100 mV DC bias on the input port (...
FrontPanel Front Panel is a piece of software written in LabVIEW designed to display, record and graph the status of the CryoMech compressor and to provide alerts...
GettingStartedWithQEDMeas A brief guide to how QEDmeas works (adapted from SMP's notes from 2003). Please update and add images etc. Concept The idea of QEDmeas...
ICEcubeGasHandlingCabinet Installation of the new ICE gas handling cabinet, a manual system in replace of the old IGH to go with the K100Fridge in room LG48. *old...
IgorPro Getting Started See here for Video tutorials: http://www.wavemetrics.com/products/igorpro/videotutorials.htm Also Igo Pro has the full manual online as a...
InitialRuns Here we discuss recent issues with earlier fridge runs. Leaktesting 16th February 2011 When warming up the traps on the 14th of February a lot of m...
IssuesWithVista Suggestions from Joe Nabity regarding NPGS compatibility issues with Win 7 and/or Vista. Email from Joe to Adam March 2010 The office installati...
K100FridgeCrashInstructions This page explains what to do if the K100 fridge crashes. Don't panic. Take records and make fridge safe 1 Record P1, P2, P3, P4,...
K100 Kelvinox Dilution Fridge Operation Instructions. *These instructions need to be edited in the raw text mode! * Note that 3 spaces and an asterisk will genera...
Noise hunting on the LG48 K100 fridge Ted's notes from 1D hole wires Sept 2009 Ted's wires were not showing good steps, due to invisible noise (not visible in ...
K100ToDoList Things we need to fix/upgrade/improve on the K100. * Install the AVS47 and TS530 temperature controllers * Replace valve V12A * Install the...
WG8 Big Kelvinox Dilution Fridge Operation Instructions. Instructions copied from QED server by ARH from APM's file dated 4 March 2003. 1. First cooldown. 1.1 P...
First Cooldown Cooling from RT to 77K. * Dripper should be out of the transfer port on the cryostat and N/V shut. This port is used to put LN in the main bat...
K400FridgeSOPCrash The fridge has crashed. If you are reading this for the first time and freaking out, open 9 and let the mixture into the dumps, take a deep bre...
K400FridgeSOPCryopump Procedure for removing mash from the 3He circuit with a cryopump for maintenance on cabinet valves, 3He pump, etc. This procedure assumes ...
K400FridgeSOPRemoval Removing the fridge from the dewar 1. Make the sample safe * Ground all gates, disconnect device, ground ohmics, Field @ 0T, RuOx off. ...
K400FridgeSOPRestarting Restarting the fridge 1. Stop pumping lines and IVC * Seal IVC at top of fridge, turn of turbo pump and disconnect. * Stop pumping...
WG8 Big Kelvinox Dilution Fridge Operation Instructions. Instructions copied from QED server by ARH from APM's file dated 4 March 2003. First cooldown. This is o...
Stocktake of Keithly SMU As of 16/10/2009 there are: 1 Keithly 2400 in WG9 on the measurement rack next to the Heliox. 1 Keithly 236 in LG48 on the organic measur...
LG48VariableTemperatureInsert This is the page for the VTI insert that is used in LG48. Standard Operating Procedure This procedure written by Ted Martin May 200...
LaTex LaTex the document processing system. There are plenty of good sites on the web on how to use LaTex etc.Here we just list how to get started. Installati...
LabMicroscopePhotography How to take photos using the lab microscope (currently in LG48 27/9/11) Setting up the camera 1 Find the lab camera (Nikon D40). It...
LabToDoList QED Labs To Do List things that need to be doneSee also WishList QEDMeas 1. Fix up sweep vi logic : If target Start step size goto target 2. Crea...
LevelMonitor Level Monitor is a piece of software written in LabVIEW designed to display, record and graph the helium level of the dewar attached to the compresso...
Li75A NF LI75A Low Noise Preamplifier The manual is attached here: LI 7576PS70A.pdf DC power supply info: Another_DC_power_supply_instead_of_PS 70A.pdf ...